"""Conversion tool from SQD to FIF. RawKIT class is adapted from Denis Engemann et al.'s mne_bti2fiff.py. """ # Authors: The MNE-Python contributors. # License: BSD-3-Clause # Copyright the MNE-Python contributors. from collections import OrderedDict, defaultdict from math import cos, sin from os import SEEK_CUR, PathLike from os import path as op from pathlib import Path import numpy as np from ..._fiff.constants import FIFF from ..._fiff.meas_info import _empty_info from ..._fiff.pick import pick_types from ..._fiff.utils import _mult_cal_one from ...epochs import BaseEpochs from ...event import read_events from ...transforms import Transform, als_ras_trans, apply_trans from ...utils import ( _check_fname, _check_option, _stamp_to_dt, fill_doc, logger, verbose, warn, ) from ..base import BaseRaw from .constants import KIT, LEGACY_AMP_PARAMS from .coreg import _set_dig_kit, read_mrk FLOAT64 = "<f8" UINT32 = "<u4" INT32 = "<i4" def _call_digitization(info, mrk, elp, hsp, kit_info, *, bad_coils=()): # Use values from kit_info only if all others are None if mrk is None and elp is None and hsp is None: mrk = kit_info.get("mrk", None) elp = kit_info.get("elp", None) hsp = kit_info.get("hsp", None) # prepare mrk if isinstance(mrk, list): mrk = [ read_mrk(marker) if isinstance(marker, str | Path | PathLike) else marker for marker in mrk ] mrk = np.mean(mrk, axis=0) # setup digitization if mrk is not None and elp is not None and hsp is not None: with info._unlock(): info["dig"], info["dev_head_t"], info["hpi_results"] = _set_dig_kit( mrk, elp, hsp, kit_info["eeg_dig"], bad_coils=bad_coils, ) elif mrk is not None or elp is not None or hsp is not None: raise ValueError( "mrk, elp and hsp need to be provided as a group (all or none)" ) return info class UnsupportedKITFormat(ValueError): """Our reader is not guaranteed to work with old files.""" def __init__(self, sqd_version, *args, **kwargs): self.sqd_version = sqd_version ValueError.__init__(self, *args, **kwargs) @fill_doc class RawKIT(BaseRaw): r"""Raw object from KIT SQD file. Parameters ---------- input_fname : path-like Path to the SQD file. %(kit_mrk)s %(kit_elp)s %(kit_hsp)s %(kit_stim)s %(kit_slope)s %(kit_stimthresh)s %(preload)s %(kit_stimcode)s allow_unknown_format : bool Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. %(standardize_names)s %(kit_badcoils)s %(verbose)s Notes ----- ``elp`` and ``hsp`` are usually the exported text files (*.txt) from the Polhemus FastScan system. ``hsp`` refers to the headshape surface points. ``elp`` refers to the points in head-space that corresponds to the HPI points. If ``mrk``\, ``hsp`` or ``elp`` are :term:`array_like` inputs, then the numbers in xyz coordinates should be in units of meters. See Also -------- mne.io.Raw : Documentation of attributes and methods. """ _extra_attributes = ("read_stim_ch",) @verbose def __init__( self, input_fname, mrk=None, elp=None, hsp=None, stim=">", slope="-", stimthresh=1, preload=False, stim_code="binary", allow_unknown_format=False, standardize_names=None, *, bad_coils=(), verbose=None, ): logger.info(f"Extracting SQD Parameters from {input_fname}...") input_fname = op.abspath(input_fname) self.preload = False logger.info("Creating Raw.info structure...") info, kit_info = get_kit_info( input_fname, allow_unknown_format, standardize_names ) kit_info["slope"] = slope kit_info["stimthresh"] = stimthresh if kit_info["acq_type"] != KIT.CONTINUOUS: raise TypeError("SQD file contains epochs, not raw data. Wrong reader.") logger.info("Creating Info structure...") last_samps = [kit_info["n_samples"] - 1] self._raw_extras = [kit_info] _set_stimchannels(self, info, stim, stim_code) super().__init__( info, preload, last_samps=last_samps, filenames=[input_fname], raw_extras=self._raw_extras, verbose=verbose, ) self.info = _call_digitization( info=self.info, mrk=mrk, elp=elp, hsp=hsp, kit_info=kit_info, bad_coils=bad_coils, ) logger.info("Ready.") def read_stim_ch(self, buffer_size=1e5): """Read events from data. Parameter --------- buffer_size : int The size of chunk to by which the data are scanned. Returns ------- events : array, [samples] The event vector (1 x samples). """ buffer_size = int(buffer_size) start = int(self.first_samp) stop = int(self.last_samp + 1) pick = pick_types(self.info, meg=False, ref_meg=False, stim=True, exclude=[]) stim_ch = np.empty((1, stop), dtype=np.int64) for b_start in range(start, stop, buffer_size): b_stop = b_start + buffer_size x = self[pick, b_start:b_stop][0] stim_ch[:, b_start : b_start + x.shape[1]] = x return stim_ch def _read_segment_file(self, data, idx, fi, start, stop, cals, mult): """Read a chunk of raw data.""" sqd = self._raw_extras[fi] nchan = sqd["nchan"] data_left = (stop - start) * nchan conv_factor = sqd["conv_factor"] n_bytes = sqd["dtype"].itemsize assert n_bytes in (2, 4) # Read up to 100 MB of data at a time. blk_size = min(data_left, (100000000 // n_bytes // nchan) * nchan) with open(self.filenames[fi], "rb", buffering=0) as fid: # extract data pointer = start * nchan * n_bytes fid.seek(sqd["dirs"][KIT.DIR_INDEX_RAW_DATA]["offset"] + pointer) stim = sqd["stim"] for blk_start in np.arange(0, data_left, blk_size) // nchan: blk_size = min(blk_size, data_left - blk_start * nchan) block = np.fromfile(fid, dtype=sqd["dtype"], count=blk_size) block = block.reshape(nchan, -1, order="F").astype(float) blk_stop = blk_start + block.shape[1] data_view = data[:, blk_start:blk_stop] block *= conv_factor # Create a synthetic stim channel if stim is not None: stim_ch = _make_stim_channel( block[stim, :], sqd["slope"], sqd["stimthresh"], sqd["stim_code"], stim, ) block = np.vstack((block, stim_ch)) _mult_cal_one(data_view, block, idx, cals, mult) # cals are all unity, so can be ignored def _set_stimchannels(inst, info, stim, stim_code): """Specify how the trigger channel is synthesized from analog channels. Has to be done before loading data. For a RawKIT instance that has been created with preload=True, this method will raise a NotImplementedError. Parameters ---------- %(info_not_none)s stim : list of int | '<' | '>' Can be submitted as list of trigger channels. If a list is not specified, the default triggers extracted from misc channels will be used with specified directionality. '<' means that largest values assigned to the first channel in sequence. '>' means the largest trigger assigned to the last channel in sequence. stim_code : 'binary' | 'channel' How to decode trigger values from stim channels. 'binary' read stim channel events as binary code, 'channel' encodes channel number. """ if inst.preload: raise NotImplementedError("Can't change stim channel after loading data") _check_option("stim_code", stim_code, ["binary", "channel"]) if stim is not None: if isinstance(stim, str): picks = _default_stim_chs(info) if stim == "<": stim = picks[::-1] elif stim == ">": stim = picks else: raise ValueError( f"stim needs to be list of int, '>' or '<', not {str(stim)!r}" ) else: stim = np.asarray(stim, int) if stim.max() >= inst._raw_extras[0]["nchan"]: raise ValueError( f"Got stim={stim}, but sqd file only has " f"{inst._raw_extras[0]['nchan']} channels." ) # modify info nchan = inst._raw_extras[0]["nchan"] + 1 info["chs"].append( dict( cal=KIT.CALIB_FACTOR, logno=nchan, scanno=nchan, range=1.0, unit=FIFF.FIFF_UNIT_NONE, unit_mul=FIFF.FIFF_UNITM_NONE, ch_name="STI 014", coil_type=FIFF.FIFFV_COIL_NONE, loc=np.full(12, np.nan), kind=FIFF.FIFFV_STIM_CH, coord_frame=FIFF.FIFFV_COORD_UNKNOWN, ) ) info._update_redundant() inst._raw_extras[0]["stim"] = stim inst._raw_extras[0]["stim_code"] = stim_code def _default_stim_chs(info): """Return default stim channels for SQD files.""" return pick_types(info, meg=False, ref_meg=False, misc=True, exclude=[])[:8] def _make_stim_channel(trigger_chs, slope, threshold, stim_code, trigger_values): """Create synthetic stim channel from multiple trigger channels.""" if slope == "+": trig_chs_bin = trigger_chs > threshold elif slope == "-": trig_chs_bin = trigger_chs < threshold else: raise ValueError("slope needs to be '+' or '-'") # trigger value if stim_code == "binary": trigger_values = 2 ** np.arange(len(trigger_chs)) elif stim_code != "channel": raise ValueError( f"stim_code must be 'binary' or 'channel', got {repr(stim_code)}" ) trig_chs = trig_chs_bin * trigger_values[:, np.newaxis] return np.array(trig_chs.sum(axis=0), ndmin=2) @fill_doc class EpochsKIT(BaseEpochs): """Epochs Array object from KIT SQD file. Parameters ---------- input_fname : path-like Path to the sqd file. events : array of int, shape (n_events, 3) | path-like The array of :term:`events`. The first column contains the event time in samples, with :term:`first_samp` included. The third column contains the event id. If a path, must yield a ``.txt`` file containing the events. If some events don't match the events of interest as specified by ``event_id``, they will be marked as ``IGNORED`` in the drop log. %(event_id)s tmin : float Start time before event. %(baseline_epochs)s %(reject_epochs)s %(flat)s %(epochs_reject_tmin_tmax)s %(kit_mrk)s %(kit_elp)s %(kit_hsp)s allow_unknown_format : bool Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. %(standardize_names)s %(verbose)s Notes ----- ``elp`` and ``hsp`` are usually the exported text files (*.txt) from the Polhemus FastScan system. hsp refers to the headshape surface points. elp refers to the points in head-space that corresponds to the HPI points. Currently, '*.elp' and '*.hsp' files are NOT supported. See Also -------- mne.Epochs : Documentation of attributes and methods. """ @verbose def __init__( self, input_fname, events, event_id=None, tmin=0, baseline=None, reject=None, flat=None, reject_tmin=None, reject_tmax=None, mrk=None, elp=None, hsp=None, allow_unknown_format=False, standardize_names=None, verbose=None, ): if isinstance(events, str | PathLike | Path): events = read_events(events) input_fname = str( _check_fname(fname=input_fname, must_exist=True, overwrite="read") ) logger.info(f"Extracting KIT Parameters from {input_fname}...") self.info, kit_info = get_kit_info( input_fname, allow_unknown_format, standardize_names ) kit_info.update(input_fname=input_fname) self._raw_extras = [kit_info] self.filenames = [] if len(events) != self._raw_extras[0]["n_epochs"]: raise ValueError("Event list does not match number of epochs.") if self._raw_extras[0]["acq_type"] == KIT.EPOCHS: self._raw_extras[0]["data_length"] = KIT.INT else: raise TypeError( "SQD file contains raw data, not epochs or average. Wrong reader." ) if event_id is None: # convert to int to make typing-checks happy event_id = {str(e): int(e) for e in np.unique(events[:, 2])} for key, val in event_id.items(): if val not in events[:, 2]: raise ValueError(f"No matching events found for {key} (event id {val})") data = self._read_kit_data() assert data.shape == ( self._raw_extras[0]["n_epochs"], self.info["nchan"], self._raw_extras[0]["frame_length"], ) tmax = ((data.shape[2] - 1) / self.info["sfreq"]) + tmin super().__init__( self.info, data, events, event_id, tmin, tmax, baseline, reject=reject, flat=flat, reject_tmin=reject_tmin, reject_tmax=reject_tmax, filename=input_fname, verbose=verbose, ) self.info = _call_digitization( info=self.info, mrk=mrk, elp=elp, hsp=hsp, kit_info=kit_info ) logger.info("Ready.") def _read_kit_data(self): """Read epochs data. Returns ------- data : array, [channels x samples] the data matrix (channels x samples). times : array, [samples] returns the time values corresponding to the samples. """ info = self._raw_extras[0] epoch_length = info["frame_length"] n_epochs = info["n_epochs"] n_samples = info["n_samples"] input_fname = info["input_fname"] dtype = info["dtype"] nchan = info["nchan"] with open(input_fname, "rb", buffering=0) as fid: fid.seek(info["dirs"][KIT.DIR_INDEX_RAW_DATA]["offset"]) count = n_samples * nchan data = np.fromfile(fid, dtype=dtype, count=count) data = data.reshape((n_samples, nchan)).T data = data * info["conv_factor"] data = data.reshape((nchan, n_epochs, epoch_length)) data = data.transpose((1, 0, 2)) return data def _read_dir(fid): return dict( offset=np.fromfile(fid, UINT32, 1)[0], size=np.fromfile(fid, INT32, 1)[0], max_count=np.fromfile(fid, INT32, 1)[0], count=np.fromfile(fid, INT32, 1)[0], ) @verbose def _read_dirs(fid, verbose=None): dirs = list() dirs.append(_read_dir(fid)) for ii in range(dirs[0]["count"] - 1): logger.debug(f" KIT dir entry {ii} @ {fid.tell()}") dirs.append(_read_dir(fid)) assert len(dirs) == dirs[KIT.DIR_INDEX_DIR]["count"] return dirs @verbose def get_kit_info(rawfile, allow_unknown_format, standardize_names=None, verbose=None): """Extract all the information from the sqd/con file. Parameters ---------- rawfile : path-like KIT file to be read. allow_unknown_format : bool Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. %(standardize_names)s %(verbose)s Returns ------- %(info_not_none)s sqd : dict A dict containing all the sqd parameter settings. """ sqd = dict() sqd["rawfile"] = rawfile unsupported_format = False with open(rawfile, "rb", buffering=0) as fid: # buffering=0 for np bug # # directories (0) # sqd["dirs"] = dirs = _read_dirs(fid) # # system (1) # fid.seek(dirs[KIT.DIR_INDEX_SYSTEM]["offset"]) # check file format version version, revision = np.fromfile(fid, INT32, 2) if version < 2 or (version == 2 and revision < 3): version_string = f"V{version}R{revision:03d}" if allow_unknown_format: unsupported_format = True warn(f"Force loading KIT format {version_string}") else: raise UnsupportedKITFormat( version_string, f"SQD file format {version_string} is not officially supported. " "Set allow_unknown_format=True to load it anyways.", ) sysid = np.fromfile(fid, INT32, 1)[0] # basic info system_name = _read_name(fid, n=128) # model name model_name = _read_name(fid, n=128) # channels sqd["nchan"] = channel_count = int(np.fromfile(fid, INT32, 1)[0]) comment = _read_name(fid, n=256) create_time, last_modified_time = np.fromfile(fid, INT32, 2) del last_modified_time fid.seek(KIT.INT * 3, SEEK_CUR) # reserved dewar_style = np.fromfile(fid, INT32, 1)[0] fid.seek(KIT.INT * 3, SEEK_CUR) # spare fll_type = np.fromfile(fid, INT32, 1)[0] fid.seek(KIT.INT * 3, SEEK_CUR) # spare trigger_type = np.fromfile(fid, INT32, 1)[0] fid.seek(KIT.INT * 3, SEEK_CUR) # spare adboard_type = np.fromfile(fid, INT32, 1)[0] fid.seek(KIT.INT * 29, SEEK_CUR) # reserved if version < 2 or (version == 2 and revision <= 3): adc_range = float(np.fromfile(fid, INT32, 1)[0]) else: adc_range = np.fromfile(fid, FLOAT64, 1)[0] adc_polarity, adc_allocated, adc_stored = np.fromfile(fid, INT32, 3) del adc_polarity system_name = system_name.replace("\x00", "") system_name = system_name.strip().replace("\n", "/") model_name = model_name.replace("\x00", "") model_name = model_name.strip().replace("\n", "/") full_version = f"V{version:d}R{revision:03d}" logger.debug("SQD file basic information:") logger.debug("Meg160 version = %s", full_version) logger.debug("System ID = %i", sysid) logger.debug("System name = %s", system_name) logger.debug("Model name = %s", model_name) logger.debug("Channel count = %i", channel_count) logger.debug("Comment = %s", comment) logger.debug("Dewar style = %i", dewar_style) logger.debug("FLL type = %i", fll_type) logger.debug("Trigger type = %i", trigger_type) logger.debug("A/D board type = %i", adboard_type) logger.debug("ADC range = +/-%s[V]", adc_range / 2.0) logger.debug("ADC allocate = %i[bit]", adc_allocated) logger.debug("ADC bit = %i[bit]", adc_stored) # MGH description: 'acquisition (megacq) VectorView system at NMR-MGH' description = f"{system_name} ({sysid}) {full_version} {model_name}" assert adc_allocated % 8 == 0 sqd["dtype"] = np.dtype(f"<i{adc_allocated // 8}") # check that we can read this file if fll_type not in KIT.FLL_SETTINGS: fll_types = sorted(KIT.FLL_SETTINGS.keys()) use_fll_type = fll_types[np.searchsorted(fll_types, fll_type) - 1] warn( "Unknown site filter settings (FLL) for system " f'"{system_name}" model "{model_name}" (ID {sysid}), will assume FLL ' f"{fll_type}->{use_fll_type}, check your data for correctness, " "including channel scales and filter settings!" ) fll_type = use_fll_type # # channel information (4) # chan_dir = dirs[KIT.DIR_INDEX_CHANNELS] chan_offset, chan_size = chan_dir["offset"], chan_dir["size"] sqd["channels"] = channels = [] exg_gains = list() for i in range(channel_count): fid.seek(chan_offset + chan_size * i) (channel_type,) = np.fromfile(fid, INT32, 1) # System 52 mislabeled reference channels as NULL. This was fixed # in system 53; not sure about 51... if sysid == 52 and i < 160 and channel_type == KIT.CHANNEL_NULL: channel_type = KIT.CHANNEL_MAGNETOMETER_REFERENCE if channel_type in KIT.CHANNELS_MEG: if channel_type not in KIT.CH_TO_FIFF_COIL: raise NotImplementedError( "KIT channel type {channel_type} can not be read. Please " "contact the mne-python developers." ) channels.append( { "type": channel_type, # (x, y, z, theta, phi) for all MEG channels. Some channel # types have additional information which we're not using. "loc": np.fromfile(fid, dtype=FLOAT64, count=5), } ) if channel_type in KIT.CHANNEL_NAME_NCHAR: fid.seek(16, SEEK_CUR) # misc fields channels[-1]["name"] = _read_name(fid, channel_type) elif channel_type in KIT.CHANNELS_MISC: (channel_no,) = np.fromfile(fid, INT32, 1) fid.seek(4, SEEK_CUR) name = _read_name(fid, channel_type) channels.append( { "type": channel_type, "no": channel_no, "name": name, } ) if channel_type in (KIT.CHANNEL_EEG, KIT.CHANNEL_ECG): offset = 6 if channel_type == KIT.CHANNEL_EEG else 8 fid.seek(offset, SEEK_CUR) exg_gains.append(np.fromfile(fid, FLOAT64, 1)[0]) elif channel_type == KIT.CHANNEL_NULL: channels.append({"type": channel_type}) else: raise OSError("Unknown KIT channel type: {channel_type}") exg_gains = np.array(exg_gains) # # Channel sensitivity information: (5) # # only sensor channels requires gain. the additional misc channels # (trigger channels, audio and voice channels) are passed # through unaffected fid.seek(dirs[KIT.DIR_INDEX_CALIBRATION]["offset"]) # (offset [Volt], gain [Tesla/Volt]) for each channel sensitivity = np.fromfile(fid, dtype=FLOAT64, count=channel_count * 2) sensitivity.shape = (channel_count, 2) channel_offset, channel_gain = sensitivity.T assert (channel_offset == 0).all() # otherwise we have a problem # # amplifier gain (7) # fid.seek(dirs[KIT.DIR_INDEX_AMP_FILTER]["offset"]) amp_data = np.fromfile(fid, INT32, 1)[0] if fll_type >= 100: # Kapper Type # gain: mask bit gain1 = (amp_data & 0x00007000) >> 12 gain2 = (amp_data & 0x70000000) >> 28 gain3 = (amp_data & 0x07000000) >> 24 amp_gain = KIT.GAINS[gain1] * KIT.GAINS[gain2] * KIT.GAINS[gain3] # filter settings hpf = (amp_data & 0x00000700) >> 8 lpf = (amp_data & 0x00070000) >> 16 bef = (amp_data & 0x00000003) >> 0 else: # Hanger Type # gain input_gain = (amp_data & 0x1800) >> 11 output_gain = (amp_data & 0x0007) >> 0 amp_gain = KIT.GAINS[input_gain] * KIT.GAINS[output_gain] # filter settings hpf = (amp_data & 0x007) >> 4 lpf = (amp_data & 0x0700) >> 8 bef = (amp_data & 0xC000) >> 14 hpf_options, lpf_options, bef_options = KIT.FLL_SETTINGS[fll_type] sqd["highpass"] = KIT.HPFS[hpf_options][hpf] sqd["lowpass"] = KIT.LPFS[lpf_options][lpf] sqd["notch"] = KIT.BEFS[bef_options][bef] # # Acquisition Parameters (8) # fid.seek(dirs[KIT.DIR_INDEX_ACQ_COND]["offset"]) (sqd["acq_type"],) = (acq_type,) = np.fromfile(fid, INT32, 1) (sqd["sfreq"],) = np.fromfile(fid, FLOAT64, 1) if acq_type == KIT.CONTINUOUS: # samples_count, = np.fromfile(fid, INT32, 1) fid.seek(KIT.INT, SEEK_CUR) (sqd["n_samples"],) = np.fromfile(fid, INT32, 1) elif acq_type == KIT.EVOKED or acq_type == KIT.EPOCHS: (sqd["frame_length"],) = np.fromfile(fid, INT32, 1) (sqd["pretrigger_length"],) = np.fromfile(fid, INT32, 1) (sqd["average_count"],) = np.fromfile(fid, INT32, 1) (sqd["n_epochs"],) = np.fromfile(fid, INT32, 1) if acq_type == KIT.EVOKED: sqd["n_samples"] = sqd["frame_length"] else: sqd["n_samples"] = sqd["frame_length"] * sqd["n_epochs"] else: raise OSError( f"Invalid acquisition type: {acq_type}. Your file is neither " "continuous nor epoched data." ) # # digitization information (12 and 26) # dig_dir = dirs[KIT.DIR_INDEX_DIG_POINTS] cor_dir = dirs[KIT.DIR_INDEX_COREG] dig = dict() hsp = list() if dig_dir["count"] > 0 and cor_dir["count"] > 0: # directories (0) fid.seek(dig_dir["offset"]) for _ in range(dig_dir["count"]): name = _read_name(fid, n=8).strip() # Sometimes there are mismatches (e.g., AFz vs AFZ) between # the channel name and its digitized, name, so let's be case # insensitive. It will also prevent collisions with HSP name = name.lower() rr = np.fromfile(fid, FLOAT64, 3) if name: assert name not in dig dig[name] = rr else: hsp.append(rr) # nasion, lpa, rpa, HPI in native space elp = [] for key in ( "fidnz", "fidt9", "fidt10", "hpi_1", "hpi_2", "hpi_3", "hpi_4", "hpi_5", ): if key in dig and np.isfinite(dig[key]).all(): elp.append(dig.pop(key)) elp = np.array(elp) hsp = np.array(hsp, float).reshape(-1, 3) if elp.shape not in ((6, 3), (7, 3), (8, 3)): raise RuntimeError(f"Fewer than 3 HPI coils found, got {len(elp) - 3}") # coregistration fid.seek(cor_dir["offset"]) mrk = np.zeros((elp.shape[0] - 3, 3)) meg_done = [True] * 5 for _ in range(cor_dir["count"]): done = np.fromfile(fid, INT32, 1)[0] fid.seek( 16 * KIT.DOUBLE + 16 * KIT.DOUBLE, # meg_to_mri # mri_to_meg SEEK_CUR, ) marker_count = np.fromfile(fid, INT32, 1)[0] if not done: continue assert marker_count >= len(mrk) for mi in range(len(mrk)): mri_type, meg_type, mri_done, this_meg_done = np.fromfile( fid, INT32, 4 ) del mri_type, meg_type, mri_done meg_done[mi] = bool(this_meg_done) fid.seek(3 * KIT.DOUBLE, SEEK_CUR) # mri_pos mrk[mi] = np.fromfile(fid, FLOAT64, 3) fid.seek(256, SEEK_CUR) # marker_file (char) if not all(meg_done): logger.info( f"Keeping {sum(meg_done)}/{len(meg_done)} HPI " "coils that were digitized" ) elp = elp[[True] * 3 + meg_done] mrk = mrk[meg_done] sqd.update(hsp=hsp, elp=elp, mrk=mrk) # precompute conversion factor for reading data if unsupported_format: if sysid not in LEGACY_AMP_PARAMS: raise OSError(f"Legacy parameters for system ID {sysid} unavailable.") adc_range, adc_stored = LEGACY_AMP_PARAMS[sysid] is_meg = np.array([ch["type"] in KIT.CHANNELS_MEG for ch in channels]) ad_to_volt = adc_range / (2.0**adc_stored) ad_to_tesla = ad_to_volt / amp_gain * channel_gain conv_factor = np.where(is_meg, ad_to_tesla, ad_to_volt) # XXX this is a bit of a hack. Should probably do this more cleanly at # some point... the 2 ** (adc_stored - 14) was empirically determined using # the test files with known amplitudes. The conv_factors need to be # replaced by these values otherwise we're off by a factor off 5000.0 # for the EEG data. is_exg = [ch["type"] in (KIT.CHANNEL_EEG, KIT.CHANNEL_ECG) for ch in channels] exg_gains /= 2.0 ** (adc_stored - 14) exg_gains[exg_gains == 0] = ad_to_volt conv_factor[is_exg] = exg_gains sqd["conv_factor"] = conv_factor[:, np.newaxis] # Create raw.info dict for raw fif object with SQD data info = _empty_info(float(sqd["sfreq"])) info.update( meas_date=_stamp_to_dt((create_time, 0)), lowpass=sqd["lowpass"], highpass=sqd["highpass"], kit_system_id=sysid, description=description, dev_head_t=Transform("meg", "head"), ) # Creates a list of dicts of meg channels for raw.info logger.info("Setting channel info structure...") info["chs"] = fiff_channels = [] channel_index = defaultdict(lambda: 0) sqd["eeg_dig"] = OrderedDict() for idx, ch in enumerate(channels, 1): if ch["type"] in KIT.CHANNELS_MEG: ch_name = ch.get("name", "") if ch_name == "" or standardize_names: ch_name = f"MEG {idx:03d}" # create three orthogonal vector # ch_angles[0]: theta, ch_angles[1]: phi theta, phi = np.radians(ch["loc"][3:]) x = sin(theta) * cos(phi) y = sin(theta) * sin(phi) z = cos(theta) vec_z = np.array([x, y, z]) vec_z /= np.linalg.norm(vec_z) vec_x = np.zeros(vec_z.size, dtype=np.float64) if vec_z[1] < vec_z[2]: if vec_z[0] < vec_z[1]: vec_x[0] = 1.0 else: vec_x[1] = 1.0 elif vec_z[0] < vec_z[2]: vec_x[0] = 1.0 else: vec_x[2] = 1.0 vec_x -= np.sum(vec_x * vec_z) * vec_z vec_x /= np.linalg.norm(vec_x) vec_y = np.cross(vec_z, vec_x) # transform to Neuromag like coordinate space vecs = np.vstack((ch["loc"][:3], vec_x, vec_y, vec_z)) vecs = apply_trans(als_ras_trans, vecs) unit = FIFF.FIFF_UNIT_T loc = vecs.ravel() else: ch_type_label = KIT.CH_LABEL[ch["type"]] channel_index[ch_type_label] += 1 ch_type_index = channel_index[ch_type_label] ch_name = ch.get("name", "") eeg_name = ch_name.lower() # some files have all EEG labeled as EEG if ch_name in ("", "EEG") or standardize_names: ch_name = f"{ch_type_label} {ch_type_index:03d}" unit = FIFF.FIFF_UNIT_V loc = np.zeros(12) if eeg_name and eeg_name in dig: loc[:3] = sqd["eeg_dig"][eeg_name] = dig[eeg_name] fiff_channels.append( dict( cal=KIT.CALIB_FACTOR, logno=idx, scanno=idx, range=KIT.RANGE, unit=unit, unit_mul=KIT.UNIT_MUL, ch_name=ch_name, coord_frame=FIFF.FIFFV_COORD_DEVICE, coil_type=KIT.CH_TO_FIFF_COIL[ch["type"]], kind=KIT.CH_TO_FIFF_KIND[ch["type"]], loc=loc, ) ) info._unlocked = False info._update_redundant() return info, sqd def _read_name(fid, ch_type=None, n=None): n = n if ch_type is None else KIT.CHANNEL_NAME_NCHAR[ch_type] return fid.read(n).split(b"\x00")[0].decode("utf-8") @fill_doc def read_raw_kit( input_fname, mrk=None, elp=None, hsp=None, stim=">", slope="-", stimthresh=1, preload=False, stim_code="binary", allow_unknown_format=False, standardize_names=False, *, bad_coils=(), verbose=None, ) -> RawKIT: r"""Reader function for Ricoh/KIT conversion to FIF. Parameters ---------- input_fname : path-like Path to the SQD file. %(kit_mrk)s %(kit_elp)s %(kit_hsp)s %(kit_stim)s %(kit_slope)s %(kit_stimthresh)s %(preload)s %(kit_stimcode)s allow_unknown_format : bool Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. %(standardize_names)s %(kit_badcoils)s %(verbose)s Returns ------- raw : instance of RawKIT A Raw object containing KIT data. See :class:`mne.io.Raw` for documentation of attributes and methods. See Also -------- mne.io.Raw : Documentation of attributes and methods of RawKIT. Notes ----- ``elp`` and ``hsp`` are usually the exported text files (\*.txt) from the Polhemus FastScan system. ``hsp`` refers to the headshape surface points. ``elp`` refers to the points in head-space that corresponds to the HPI points. If ``mrk``\, ``hsp`` or ``elp`` are :term:`array_like` inputs, then the numbers in xyz coordinates should be in units of meters. """ return RawKIT( input_fname=input_fname, mrk=mrk, elp=elp, hsp=hsp, stim=stim, slope=slope, stimthresh=stimthresh, preload=preload, stim_code=stim_code, allow_unknown_format=allow_unknown_format, standardize_names=standardize_names, bad_coils=bad_coils, verbose=verbose, ) @fill_doc def read_epochs_kit( input_fname, events, event_id=None, mrk=None, elp=None, hsp=None, allow_unknown_format=False, standardize_names=False, verbose=None, ) -> EpochsKIT: """Reader function for Ricoh/KIT epochs files. Parameters ---------- input_fname : path-like Path to the SQD file. events : array of int, shape (n_events, 3) | path-like The array of :term:`events`. The first column contains the event time in samples, with :term:`first_samp` included. The third column contains the event id. If a path, must yield a ``.txt`` file containing the events. If some events don't match the events of interest as specified by ``event_id``, they will be marked as ``IGNORED`` in the drop log. %(event_id)s %(kit_mrk)s %(kit_elp)s %(kit_hsp)s allow_unknown_format : bool Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. %(standardize_names)s %(verbose)s Returns ------- EpochsKIT : instance of BaseEpochs The epochs. See Also -------- mne.Epochs : Documentation of attributes and methods. Notes ----- .. versionadded:: 0.9.0 """ epochs = EpochsKIT( input_fname=input_fname, events=events, event_id=event_id, mrk=mrk, elp=elp, hsp=hsp, allow_unknown_format=allow_unknown_format, standardize_names=standardize_names, verbose=verbose, ) return epochs
"""Conversion tool from SQD to FIF.
RawKIT class is adapted from Denis Engemann et al.'s mne_bti2fiff.py.
"""
# Authors: The MNE-Python contributors.
# License: BSD-3-Clause
# Copyright the MNE-Python contributors.
from collections import OrderedDict, defaultdict
from math import cos, sin
from os import SEEK_CUR, PathLike
from os import path as op
from pathlib import Path
import numpy as np
from ..._fiff.constants import FIFF
from ..._fiff.meas_info import _empty_info
from ..._fiff.pick import pick_types
from ..._fiff.utils import _mult_cal_one
from ...epochs import BaseEpochs
from ...event import read_events
from ...transforms import Transform, als_ras_trans, apply_trans
from ...utils import (
_check_fname,
_check_option,
_stamp_to_dt,
fill_doc,
logger,
verbose,
warn,
)
from ..base import BaseRaw
from .constants import KIT, LEGACY_AMP_PARAMS
from .coreg import _set_dig_kit, read_mrk
FLOAT64 = "<f8"
UINT32 = "<u4"
INT32 = "<i4"
def _call_digitization(info, mrk, elp, hsp, kit_info, *, bad_coils=()):
# Use values from kit_info only if all others are None
if mrk is None and elp is None and hsp is None:
mrk = kit_info.get("mrk", None)
elp = kit_info.get("elp", None)
hsp = kit_info.get("hsp", None)
# prepare mrk
if isinstance(mrk, list):
mrk = [
read_mrk(marker) if isinstance(marker, str | Path | PathLike) else marker
for marker in mrk
]
mrk = np.mean(mrk, axis=0)
# setup digitization
if mrk is not None and elp is not None and hsp is not None:
with info._unlock():
info["dig"], info["dev_head_t"], info["hpi_results"] = _set_dig_kit(
mrk,
elp,
hsp,
kit_info["eeg_dig"],
bad_coils=bad_coils,
)
elif mrk is not None or elp is not None or hsp is not None:
raise ValueError(
"mrk, elp and hsp need to be provided as a group (all or none)"
)
return info
class UnsupportedKITFormat(ValueError):
"""Our reader is not guaranteed to work with old files."""
def __init__(self, sqd_version, *args, **kwargs):
self.sqd_version = sqd_version
ValueError.__init__(self, *args, **kwargs)
@fill_doc
class RawKIT(BaseRaw):
r"""Raw object from KIT SQD file.
Parameters
----------
input_fname : path-like
Path to the SQD file.
%(kit_mrk)s
%(kit_elp)s
%(kit_hsp)s
%(kit_stim)s
%(kit_slope)s
%(kit_stimthresh)s
%(preload)s
%(kit_stimcode)s
allow_unknown_format : bool